Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Más filtros










Intervalo de año de publicación
1.
Sensors (Basel) ; 22(7)2022 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-35408266

RESUMEN

Research has shown that longitudinal chromatic aberration (LCA) of the human eye is generated across all of the eye's optical surfaces. However, it may not be necessary to measure the LCA from the first surface of the cornea to the retina, as it is known that most of the changes that can modify the path of light occur from the first surface of the cornea to the last surface of the crystalline lens. This investigation presents the study of an objective technique that allows the measurement of longitudinal chromatic aberration (LCA) on the last crystalline lens surface by developing a pulse width wavefront system using a Hartmann test, Purkinje image, and Zernike polynomial. A blue pulse (440-480 nm) and a red pulse (580-640 nm) were used to generate a pattern of spots in the human eye. This pattern generated on the posterior surface of the crystalline lens of the human eye allows the reconstruction of the wavefront via a modal method with Zernike polynomials. Once the wavefront is reconstructed, Zernike coefficients can be used to quantify the LCA. The methodology and objective measurements of the magnitude of the longitudinal chromatic aberration of five test subjects are explained in this article.


Asunto(s)
Cristalino , Errores de Refracción , Algoritmos , Córnea , Humanos , Visión Ocular
2.
J Opt Soc Am A Opt Image Sci Vis ; 30(12): 2595-604, 2013 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-24323021

RESUMEN

Adaptive optics (AO) imaging methods allow the histological characteristics of retinal cell mosaics, such as photoreceptors and retinal pigment epithelium (RPE) cells, to be studied in vivo. The high-resolution images obtained with ophthalmic AO imaging devices are rich with information that is difficult and/or tedious to quantify using manual methods. Thus, robust, automated analysis tools that can provide reproducible quantitative information about the cellular mosaics under examination are required. Automated algorithms have been developed to detect the position of individual photoreceptor cells; however, most of these methods are not well suited for characterizing the RPE mosaic. We have developed an algorithm for RPE cell segmentation and show its performance here on simulated and real fluorescence AO images of the RPE mosaic. Algorithm performance was compared to manual cell identification and yielded better than 91% correspondence. This method can be used to segment RPE cells for morphometric analysis of the RPE mosaic and speed the analysis of both healthy and diseased RPE mosaics.


Asunto(s)
Células Epiteliales/fisiología , Epitelio Pigmentado de la Retina/patología , Algoritmos , Animales , Automatización , Simulación por Computador , Fluorescencia , Humanos , Procesamiento de Imagen Asistido por Computador , Luz , Macaca , Microscopía Fluorescente/métodos , Distribución Normal , Oftalmoscopía/métodos , Óptica y Fotónica , Epitelio Pigmentado de la Retina/citología
3.
Appl Opt ; 50(7): 1057-64, 2011 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-21364730

RESUMEN

The main constraint of classical off-axis reflecting systems is the primary astigmatism that has long been a research topic of interest. This astigmatism in off-axis spherical reflective imaging systems can be eliminated by using the proper configuration. These configurations could be derived from the marginal ray fans equation, and they are valid for small angles of incidence. The conditions for the astigmatism compensation in configurations with two and three off-axis mirrors have been derived and analyzed, which have not been reported previously. The expression that defines the conditions for primary astigmatism compensation in a four-mirror system is presented. This shows that the marginal ray fan equation can be used to obtain the condition for astigmatism compensation of a reflective system with any number of mirrors. The developed methodology is verified by ray-tracing analysis of some examples.

4.
Appl Opt ; 50(1): 66-73, 2011 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-21221162

RESUMEN

We present, analyze, and evaluate expressions for the wavefront aberrations in an off-axis spherical mirror. These formulas are derived from the optical path difference between an ellipsoid and a sphere, assuming a relatively small pupil and a small angle of incidence, as will be described in detail. Some well-known and also some useful new aberration expressions are obtained. They can be used to design and analyze cavities, spectrographs, and retinal adaptive optics imaging systems.

5.
Appl Opt ; 49(12): 2302-8, 2010 Apr 20.
Artículo en Inglés | MEDLINE | ID: mdl-20411009

RESUMEN

A wavefront aberration can be retrieved from a defocused image or a Hartmanngram by several different methods using diffraction theory and Fourier transforms. In this manuscript, we describe an alternate method for wavefront aberration determination from a defocused image or a Hartmanngram using a geometric l approximation. The main assumption is that the image is defocused, with the observation plane outside the caustic limits. The result will be applied to the retrieval of a wavefront with primary aberrations from a Hartmanngram or defocused image without the need for any transversal aberration integration.

6.
Opt Express ; 17(21): 18906-19, 2009 Oct 12.
Artículo en Inglés | MEDLINE | ID: mdl-20372626

RESUMEN

Expressions for minimal astigmatism in image and pupil planes in off-axis afocal reflective telescopes formed by pairs of spherical mirrors are presented. These formulae which are derived from the marginal ray fan equation can be used for designing laser cavities, spectrographs and adaptive optics retinal imaging systems. The use, range and validity of these formulae are limited by spherical aberration and coma for small and large angles respectively. This is discussed using examples from adaptive optics retinal imaging systems. The performance of the resulting optical designs are evaluated and compared against the configurations with minimal wavefront RMS, using the defocus-corrected wavefront RMS as a metric.

9.
Rev. panam. salud pública ; 19(6): 417-422, jun. 2006. tab
Artículo en Inglés | LILACS | ID: lil-433462

RESUMEN

Debido a los sesgos que afectan a la publicación de ensayos clínicos y sus resultados, los estudios cuyos resultados son positivos son más fáciles de encontrar que los que tienen resultados sin significación estadística y a ello se debe que los primeros estén sobrerrepresentados. Para contrarrestar este tipo de sesgo se ha propuesto ingresar en un registro toda investigación, desde sus comienzos. No obstante, estos registros se encuentran en distintas fases de evolución, especialmente en países en desarrollo, de tal manera que la Red Cochrane Iberoamericana, parte de la Colaboración Cochrane, ha establecido el Registro Latinoamericano de Ensayos Clínicos en Curso (LATINREC, por Latin American Clinical Trial Registry) con la idea de facilitar el registro de los datos contenidos en el protocolo de todo ensayo clínico que se esté llevando a cabo en un momento dado y poner esa información a la disposición del público. El LATINREC, que viene a respaldar los objetivos de la Organización Mundial de la Salud (OMS), representa un intento por reducir la duplicación de trabajo y el financiamiento poco equitativo de la investigación sobre enfermedades rezagadas al olvido; por evitar que se efectúen investigaciones sobre asuntos de poca cuantía o que se midan resultados poco útiles; y por fomentar las prácticas éticas y la transparencia. Se han detectado algunos obstáculos mayores que hasta ahora han impedido crear un registro único y común de ensayos clínicos. Con el fin de franquearlos, LATINREC será un registro gratuito que permitirá hacer búsquedas y que se ceñirá a la Plataforma Internacional de Registro de Ensayos Clínicos (ICTRP) de la OMS. Además, LATINREC permitirá que los investigadores ingresen en el registro cualquier modificación del protocolo, así como los resultados preliminares. LATINREC ofrecerá grandes ventajas para los consumidores, el gobierno, los profesionales de la salud pública y la industria farmacéutica al incrementar la accesibilidad de la información y la participación en los ensayos clínicos. La disponibilidad de información objetiva acerca de todo ensayo clínico que se inicie ayudará a garantizar que todos tengan libre acceso a los conocimientos generados.


Asunto(s)
Ensayos Clínicos como Asunto , Sistema de Registros , América Latina , Sesgo de Publicación , Edición
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...